Woltmann Water Meter LMLC
The LMLC is a heavy-duty Woltmann water meter designed for high-volume flow with minimal pressure loss. Its removable measuring insert allows easy maintenance and calibration without removing the meter body.
-
Removable mechanism for easy servicing
-
Low pressure loss for high-flow applications
-
IP68 copper/glass register – durable and sealed
-
350° rotatable head for convenient reading
-
Magnetic tamper protection
-
Optional pulse/encoder output for smart upgrades
-
ISO 4064 compliant for trusted accuracy
FEATURES
Measurement Requirements
-
Temperature Class: Cold water meter: T30 Hot water meter: T30/90
-
Pressure Rating (MAP): MAP16 (up to 16 bar)
-
Pressure Loss Class: ΔP25
-
Flow Sensitivity (Upstream): U10
-
Flow Sensitivity (Downstream): D5
Maximum Permissible Error
-
Low Flow Region (Q₁ ≤ Q < Q₂): ±5%
-
High Flow Region (Q₂ ≤ Q ≤ Q₄):
-
±2% when water temperature ≤ 30°C
-
±3% when water temperature > 30°C
-
METROLOGICAL DATA
Nominal diameter | DN | mm | 50 | 65 | 80 | 100 | 125 | 150 |
---|---|---|---|---|---|---|---|---|
Length* | L | mm | 200 | 200 | 225 | 250 | 250 | 300 |
Nominal flow rate | Q3 | m³/h | 40 | 40 | 63 | 100 | 160 | 250 |
R standard* | Q3/Q1 | R | 80 | 80 |
80 |
80 | 80 | 80 |
Minimum flow rate* | Q1 | m³/h | 0.5 | 0.5 | 0.8 | 1.3 | 2 | 3.1 |
Transition flow rate* | Q2 | m³/h | 0.8 | 0.8 | 1.3 | 2 | 3.2 | 5 |
Maximum flow rate | Q4 | m³/h | 50 | 50 | 78.8 | 125 | 200 | 312.5 |